Product Features

  • Compact and portable
  • Simple to use
  • Clear display and controls
  • Visual and audible alarm with volume control
  • Automatic output voltage selector
  • Accurate sensitivity control
  • Compatible with older PD accessories
  • Robust cast aluminium outer casing
  • One year ‘back to base’ warranty
  • CE approved

The PHD Pro’6 range of high-voltage DC holiday detectors are ideal for rapid and effective holiday testing of a wide range of non-conductive coatings and linings for porosity, faults and defects. 

Battery-powered and fully portable; the PHD Pro’6 has an output voltage range of 0.5-6kV, making it able to perform high-voltage holiday tests on coating thicknesses from 4μm to 576μm.

The PHD Pro’6S (standard) kit includes a selection of accessory and electrode options; all supplied in a protective case. An extensive range of accessories and electrodes are available separately.

We also offer a PHD Pro’6C (complete) kit is available; comprising an extensive range of accessories and electrodes; all supplied in a robust foam-lined transit case.

Standard kit includes:

  • PHD Pro’6 holiday detector, probe handle & interconnecting lead
  • Drum brush electrode
  • 4 x rechargeable D-cell batteries and charger
  • 5m earth lead on reel
  • ESD anti-static wrist band
  • Trailing earth lead
  • 1 x 332mm insulated mid-section extension rod
  • 1 x 332mm insulated end-section extension rod
  • Rolling spring electrode shoe, screwdriver & knurled locknut
  • 250mm phosphor-bronze brush electrode
  • Carry bag with shoulder strap
  • Instruction manual, calibration certificate & test voltage calculator
  • Supplied in a protective executive-style case

  • Output voltage range: 0.5 to 6kV DC
  • Alarm sensitivity range: 10 to 450μA (pre-set to 350μA)
  • Coating thickness range: 4 to 576μm
  • Built-in test voltage formula: NACE SP0274
  • Unit weight: 1.64Kg
  • Unit dimensions: 172mm x 85mm x 235mm
  • Handle weight: 720g
  • Handle dimensions: 290mm x 85mm
  • Packed weight: 11.4kg
  • Packed dimensions: 580mm x 440mm x 250mm

No questions are available at this time

Be the first to ask!



Straight Phosphor-Bronze Brush - 100mm (E104)

Straight Phosphor Bronze Brush Electrodes 100mm / 4" wide  ...

Straight Phosphor-Bronze Brush - 150mm (E106)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched. And are normally supplied with a 90° backing strip for fitting into the shoe attachment (A12). *Maximum length recommended for use with AC equipment is 150mm ...

Straight Phosphor-Bronze Brush - 200mm (E108)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched. And are normally supplied with a 90° backing strip for fitting into the shoe attachment (A12). *Maximum length recommended for use with AC equipment is 150mm ...

Straight Phosphor-Bronze Brush - 250mm (E110)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched. And are normally supplied with a 90° backing strip for fitting into the shoe attachment (A12). *Maximum length recommended for use with AC equipment is 150mm ...

Straight Phosphor-Bronze Brush - 300mm (E112)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched. And are normally supplied with a 90° backing strip for fitting into the shoe attachment (A12). *Maximum length recommended for use with AC equipment is 150mm ...

Straight Phosphor Bronze Brush - 350mm (E114)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched. And are normally supplied with a 90° backing strip for fitting into the shoe attachment (A12). *Maximum length recommended for use with AC equipment is 150mm ...

Straight Phosphor-Bronze Brush - 400mm (E116)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched. And are normally supplied with a 90° backing strip for fitting into the shoe attachment (A12). *Maximum length recommended for use with AC equipment is 150mm ...

Straight Phosphor-Bronze Brush - 450mm (E118)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched. And are normally supplied with a 90° backing strip for fitting into the shoe attachment (A12). *Maximum length recommended for use with AC equipment is 150mm ...

Straight Phosphor-Bronze Brush - 500mm (E120)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched. And are normally supplied with a 90° backing strip for fitting into the shoe attachment (A12). *Maximum length recommended for use with AC equipment is 150mm ...

Straight Phosphor-Bronze Brush - 700mm (E128)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched. And are normally supplied with a 90° backing strip for fitting into the shoe attachment (A12). *Maximum length recommended for use with AC equipment is 150mm ...

Straight Phosphor-Bronze Brush - 800mm (E132)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched. And are normally supplied with a 90° backing strip for fitting into the shoe attachment (A12). *Maximum length recommended for use with AC equipment is 150mm ...

Straight Phosphor-Bronze Brush - 1000mm (E140)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched. And are normally supplied with a 90° backing strip for fitting into the shoe attachment (A12). *Maximum length recommended for use with AC equipment is 150mm ...

Straight Phosphor-Bronze Brush - 1200mm (E148)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched. And are normally supplied with a 90° backing strip for fitting into the shoe attachment (A12). *Maximum length recommended for use with AC equipment is 150mm ...

Straight Silicone Rubber - 100mm (E204)

The straight silicone rubber electrodes are normally supplied with a 90° backing strip, for fitting into the shoe attachment (A12). They can also be supplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod, or with the Adaptor (A4), straight ont...

Straight Silicone Rubber - 150mm (E206)

The straight silicone rubber electrodes are normally supplied with a 90° backing strip, for fitting into the shoe attachment (A12). They can also be supplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod, or with the Adaptor (A4), straight ...

Straight Silicone Rubber - 200mm (E208)

The straight silicone rubber electrodes are normally supplied with a 90° backing strip, for fitting into the shoe attachment (A12). They can also be supplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod, or with the Adaptor (A4), straight ...

Straight Silicone Rubber - 250mm (E210)

The straight silicone rubber electrodes are normally supplied with a 90° backing strip, for fitting into the shoe attachment (A12). They can also be supplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod, or with the Adaptor (A4), straight ont...

Straight Silicone Rubber - 300mm (E212)

The straight silicone rubber electrodes are normally supplied with a 90° backing strip, for fitting into the shoe attachment (A12). They can also be supplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod, or with the Adaptor (A4), straight ont...

Straight Silicone Rubber - 350mm (E214)

The straight silicone rubber electrodes are normally supplied with a 90° backing strip, for fitting into the shoe attachment (A12). They can also be supplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod, or with the Adaptor (A4), straight ont...

Straight Silicone Rubber - 400mm (E216)

The straight silicone rubber electrodes are normally supplied with a 90° backing strip, for fitting into the shoe attachment (A12). They can also be supplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod, or with the Adaptor (A4), straight ont...

Straight Silicone Rubber - 450mm (E218)

The straight silicone rubber electrodes are normally supplied with a 90° backing strip, for fitting into the shoe attachment (A12). They can also be supplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod, or with the Adaptor (A4), straight ont...

Straight Silicone Rubber - 500mm (E220)

The straight silicone rubber electrodes are normally supplied with a 90° backing strip, for fitting into the shoe attachment (A12). They can also be supplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod, or with the Adaptor (A4), straight ont...

Straight Silicone Rubber - 600mm (E224)

The straight silicone rubber electrodes are normally supplied with a 90° backing strip, for fitting into the shoe attachment (A12). They can also be supplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod, or with the Adaptor (A4), straight ont...

Curved Phosphor-Bronze - 180° - 150mm (E306)

Available for pipe sizes 200mm Used for testing coatings on the outside of pipes. Curved 180° for pipes up to 800mm diameter, curved 90° for larger pipe sizes   ...

Curved Phosphor-Bronze - 180° - 200mm (E308)

Available for pipe sizes 200mm Used for testing coatings on the outside of pipes. Curved 180° for pipes up to 800mm diameter, curved 90° for larger pipe sizes ...

Curved Phosphor-Bronze - 180° - 250mm (E310)

Available for pipe sizes 200mm Used for testing coatings on the outside of pipes. Curved 180° for pipes up to 800mm diameter, curved 90° for larger pipe sizes ...

Curved Phosphor-Bronze - 180° - 300mm (E312)

Available for pipe sizes 200mm Used for testing coatings on the outside of pipes. Curved 180° for pipes up to 800mm diameter, curved 90° for larger pipe sizes ...

Curved Phosphor-Bronze - 180° - 350mm (E314)

Available for pipe sizes 200mm Used for testing coatings on the outside of pipes. Curved 180° for pipes up to 800mm diameter, curved 90° for larger pipe sizes ...

Curved Phosphor-Bronze - 180° - 400mm (E316)

Available for pipe sizes 200mm Used for testing coatings on the outside of pipes. Curved 180° for pipes up to 800mm diameter, curved 90° for larger pipe sizes ...

Curved Phosphor-Bronze - 180° - 450mm (E318)

Available for pipe sizes 200mm Used for testing coatings on the outside of pipes. Curved 180° for pipes up to 800mm diameter, curved 90° for larger pipe sizes ...

Curved Phosphor-Bronze - 180° - 500mm (E320)

Available for pipe sizes 200mm Used for testing coatings on the outside of pipes. Curved 180° for pipes up to 800mm diameter, curved 90° for larger pipe sizes ...

Curved Phosphor-Bronze - 180° - 600mm (E324)

Available for pipe sizes 200mm Used for testing coatings on the outside of pipes. Curved 180° for pipes up to 800mm diameter, curved 90° for larger pipe sizes ...

Curved Phosphor-Bronze - 180° - 700mm (E328)

Available for pipe sizes 200mm Used for testing coatings on the outside of pipes. Curved 180° for pipes up to 800mm diameter, curved 90° for larger pipe sizes ...

Curved Phosphor-Bronze - 180° - 750mm (E330)

Available for pipe sizes 200mm Used for testing coatings on the outside of pipes. Curved 180° for pipes up to 800mm diameter, curved 90° for larger pipe sizes ...

Curved Phosphor-Bronze - 180° - 800mm (E332)

Available for pipe sizes 200mm Used for testing coatings on the outside of pipes. Curved 180° for pipes up to 800mm diameter, curved 90° for larger pipe sizes ...

Rolling Spring Electrode (complete) - 110mm (E704)

The rolling spring electrode is used for testing the coatings on the outside of pipes A Shoe Attachment (our ref: A12) is required to connect the Rolling Spring to the Holiday Detector. ...

Rolling Spring Electrode (complete) - 150mm (E706)

The rolling spring electrode is used for testing the coatings on the outside of pipes A Shoe Attachment (our ref: A12) is required to connect the Rolling Spring to the Holiday Detector. ...

Rolling Spring Electrode (complete) - 200mm (E708)

The rolling spring electrode is used for testing the coatings on the outside of pipes A Shoe Attachment (our ref: A12) is required to connect the Rolling Spring to the Holiday Detector. ...

Rolling Spring Electrode (complete) - 250mm (E710)

The rolling spring electrode is used for testing the coatings on the outside of pipes A Shoe Attachment (our ref: A12) is required to connect the Rolling Spring to the Holiday Detector. ...

Rolling Spring Electrode (complete) - 300mm (E712)

The rolling spring electrode is used for testing the coatings on the outside of pipes A Shoe Attachment (our ref: A12) is required to connect the Rolling Spring to the Holiday Detector. ...

Rolling Spring Electrode (complete) - 350mm (E714)

The rolling spring electrode is used for testing the coatings on the outside of pipes A Shoe Attachment (our ref: A12) is required to connect the Rolling Spring to the Holiday Detector ...

Rolling Spring Electrode (complete) - 400mm (E716)

The rolling spring electrode is used for testing the coatings on the outside of pipes A Shoe Attachment (our ref: A12) is required to connect the Rolling Spring to the Holiday Detector. ...

Rolling Spring Electrode (complete) - 450mm (E718)

The rolling spring electrode is used for testing the coatings on the outside of pipes A Shoe Attachment (our ref: A12) is required to connect the Rolling Spring to the Holiday Detector. ...

Rolling Spring Electrode (complete) - 500mm (E720)

The rolling spring electrode is used for testing the coatings on the outside of pipes A Shoe Attachment (our ref: A12) is required to connect the Rolling Spring to the Holiday Detector. ...

Rolling Spring Electrode (complete) - 600mm (E724)

The rolling spring electrode is used for testing the coatings on the outside of pipes A Shoe Attachment (our ref: A12) is required to connect the Rolling Spring to the Holiday Detector. ...

Rolling Spring Electrode (complete) - 650mm (E726)

The rolling spring electrode is used for testing the coatings on the outside of pipes A Shoe Attachment (our ref: A12) is required to connect the Rolling Spring to the Holiday Detector. ...

Rolling Spring Electrode (complete) - 700mm (E728)

The rolling spring electrode is used for testing the coatings on the outside of pipes A Shoe Attachment (our ref: A12) is required to connect the Rolling Spring to the Holiday Detector. ...

Rolling Spring Electrode (complete) - 800mm (E732)

The rolling spring electrode is used for testing the coatings on the outside of pipes A Shoe Attachment (our ref: A12) is required to connect the Rolling Spring to the Holiday Detector. ...

Rolling Spring Electrode (complete) - 900mm (E736)

The rolling spring electrode is used for testing the coatings on the outside of pipes A Shoe Attachment (our ref: A12) is required to connect the Rolling Spring to the Holiday Detector. ...

Rolling Spring Electrode (complete) - 1000mm (E740)

The rolling spring electrode is used for testing the coatings on the outside of pipes A Shoe Attachment (our ref: A12) is required to connect the Rolling Spring to the Holiday Detector. ...

Rolling Spring Electrode (complete) - 1050mm (E742)

The rolling spring electrode is used for testing the coatings on the outside of pipes A Shoe Attachment (our ref: A12) is required to connect the Rolling Spring to the Holiday Detector. ...

Rolling Spring Electrode (complete) - 1100mm (E744)

The rolling spring electrode is used for testing the coatings on the outside of pipes A Shoe Attachment (our ref: A12) is required to connect the Rolling Spring to the Holiday Detector. ...

Rolling Spring Electrode (complete) - 1150mm (E746)

The rolling spring electrode is used for testing the coatings on the outside of pipes A Shoe Attachment (our ref: A12) is required to connect the Rolling Spring to the Holiday Detector. ...

Rolling Spring Electrode (complete) - 1200mm (E748)

The rolling spring electrode is used for testing the coatings on the outside of pipes A Shoe Attachment (our ref: A12) is required to connect the Rolling Spring to the Holiday Detector. ...

Rolling Spring Electrode (complete) - 1295mm (E751)

The rolling spring electrode is used for testing the coatings on the outside of pipes A Shoe Attachment (our ref: A12) is required to connect the Rolling Spring to the Holiday Detector. ...

Rolling Spring Electrode (complete) - 1320mm (E752)

The rolling spring electrode is used for testing the coatings on the outside of pipes A Shoe Attachment (our ref: A12) is required to connect the Rolling Spring to the Holiday Detector. ...

Rolling Spring Electrode (complete) - 1371.60mm (E754)

The rolling spring electrode is used for testing the coatings on the outside of pipes A Shoe Attachment (our ref: A12) is required to connect the Rolling Spring to the Holiday Detector. ...

Rolling Spring Electrode (complete) - 1400mm (E756)

The rolling spring electrode is used for testing the coatings on the outside of pipes A Shoe Attachment (our ref: A12) is required to connect the Rolling Spring to the Holiday Detector. ...

Rolling Spring Electrode (complete) - 1448mm (E757)

The rolling spring electrode is used for testing the coatings on the outside of pipes A Shoe Attachment (our ref: A12) is required to connect the Rolling Spring to the Holiday Detector. ...

Rolling Spring Electrode (complete) - 1524mm (E760)

The rolling spring electrode is used for testing the coatings on the outside of pipes A Shoe Attachment (our ref: A12) is required to connect the Rolling Spring to the Holiday Detector. ...

Rolling Spring Electrode (complete) - 1600mm (E763)

The rolling spring electrode is used for testing the coatings on the outside of pipes A Shoe Attachment (our ref: A12) is required to connect the Rolling Spring to the Holiday Detector. ...

Rolling Spring Electrode (complete) - 1625mm (E764)

The rolling spring electrode is used for testing the coatings on the outside of pipes A Shoe Attachment (our ref: A12) is required to connect the Rolling Spring to the Holiday Detector. ...

Rolling Spring Electrode (complete) - 1676mm (E766)

The rolling spring electrode is used for testing the coatings on the outside of pipes A Shoe Attachment (our ref: A12) is required to connect the Rolling Spring to the Holiday Detector. ...

Straight Phosphor-Bronze Brush - 45° - 100mm (E104A)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched. They aresupplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod or, with an adaptor (A4), straight onto the test probe handle. *Maximum length re...

Straight Phosphor-Bronze Brush - 45° - 150mm (E106A)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched. They aresupplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod or, with an adaptor (A4), straight onto the test probe handle. *Maximum length re...

Straight Phosphor-Bronze Brush - 45° - 200mm (E108A)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched.They are supplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod or, with an adaptor (A4), straight onto the test probe handle.*Maximum length recommend...

Straight Phosphor-Bronze Brush - 45° - 250mm (E110A)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched.They are supplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod or, with an adaptor (A4), straight onto the test probe handle.*Maximum length recommend...

Straight Phosphor-Bronze Brush - 45° - 300mm (E112A)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched.They are supplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod or, with an adaptor (A4), straight onto the test probe handle.*Maximum length recommend...

Straight Phosphor-Bronze Brush - 45° - 400mm (E116A)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched.They are supplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod or, with an adaptor (A4), straight onto the test probe handle.*Maximum length recommend...

Straight Phosphor-Bronze Brush - 45° - 450mm (E118A)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched.They are supplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod or, with an adaptor (A4), straight onto the test probe handle.*Maximum length recommend...

Straight Phosphor-Bronze Brush - 45° - 500mm (E120A)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched.They are supplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod or, with an adaptor (A4), straight onto the test probe handle.*Maximum length recommend...

Straight Phosphor-Bronze Brush - 45° - 600mm (E124A)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched.They are supplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod or, with an adaptor (A4), straight onto the test probe handle.*Maximum length recommend...

Straight Phosphor-Bronze Brush - 45° - 700mm (E128A)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched.They are supplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod or, with an adaptor (A4), straight onto the test probe handle.*Maximum length recommend...

Straight Phosphor-Bronze Brush - 45° - 800mm (E132A)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched.They are supplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod or, with an adaptor (A4), straight onto the test probe handle.*Maximum length recommend...

Straight Phosphor-Bronze Brush - 45° - 1200mm (E148A)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched.They are supplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod or, with an adaptor (A4), straight onto the test probe handle.*Maximum length recommend...

© 2017 All Rights Reserved Buckleys (UVRAL) Ltd